“ The Leader in Engineering Service Consultants ”

  • 02 270 8899

Load Test Scheme of 32 m Simply Supported Box Beam

Project: BANGKOK - NAKHON RATCHASIMA HIGH SPEED RAILWAY PROJECT  CONTRACT 3-5

Departments:
Quality Assurance BU

Client:
China Railway 23rd Bureau Group (Thailand) Co., Ltd.

Project Type:
Load Test Scheme of 32 m Simply Supported Box Beam

Project Location:
Ban Mai Subdistrict, Mueang District, Nakhon Ratchasima Province

Project Value:
Not specified

Completion Year:
2023
Load Test Scheme of 32 m Simply Supported Box Beam, Project: BANGKOK - NAKHON RATCHASIMA HIGH-SPEED RAILWAY. 

The test involves evaluating the load-bearing behavior of the bridge (Trial span segment viaduct) using the Bending test method in accordance with the TB/T 2092-2018 standard. The maximum test load is set at 12,000 kilonewtons. Additionally, a Natural Frequency test will be conducted following the TB/T 10621-2014 standard. This test uses a 1-ton load dropped freely from a height of 1 meter to assess the structural response under load and evaluate the structural load-bearing capacity. The evaluation will be performed using a Mathematical Finite Element Model.

Department/Division: Quality Assurance Business Unit
Project Location: Ban Mai Subdistrict, Mueang District, Nakhon Ratchasima Province
Project Owner/Contractor: China Railway 23rd Bureau Group (Thailand) Co., Ltd.

For inquiries about quality assurance testing services, contact:
Line: @stsgroup
Phone: 02-270-8899 Ext. 511
Email: [email protected]
Website: www.sts.co.th